Reverse Indicator Alignment
An alignment method in which two measurements are taken on the rims of mating machinery couplings, using two dial indicators attached to rigid brackets. Shaft angularity can be calculated as the slope between the two offset dial indicator readings. This measurement normally requires the machines to be coupled.